High suction pressure and low head pressure - Positive Suction Head (NPSH)—the pressure provided at the suction of the pump less the fluid’s vapor pressure — is too low. When fluid pressure on the trailing side of the impeller blade (opposite the pump intake) falls below the vaporization point of the fluid, vapor bubbles begin to form.

 
OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 …. Brown hairstyles with lowlights

Mechanical Engineering. When a refrigeration system producing low to normal refrigeration operates continuously without stopping and has high suction pressure and high head pressure , the probable cause is 1. an inefficient compressor 2. a low side restriction 3. noncondensables trapped in the condenser 4. an undercharge of refrigerant.Low fuel pressure results in several issues for the engine, including rough idle, poor performance and decreased fuel economy. If the pressure is too low, the engine does not start...are serviceable by a manufacturer-approved repair facility will lead to compressor inefficiency may cause high suction pressure and low head pressure Correct! All of the above. A suction line may also contain a ____. ... If a condenser has high head pressure and a higher than normal temperature, a technician could ____. ...System Information R22 2.5 ton: Low Side: 115. High Side: 240. Return Air: 83. Suction Line Temp: 75. Measured Super heat: 5. Super heat should be around 15. Low superheat is an indication that liquid refrigerant not changing state in the evaporator and is possibly flooding back to the compressor.Scale results in a low head pressure in the cooling mode and high suction pressure in the heating mode False A domestic hot water loop is loop is often used for heating domestic hot water from the hot discharge gas coming from the heat pump's refrigerant compressorLower suction pressures generally result in a higher DTD, and higher suction pressures usually result in a lower DTD. When we look at head pressure, we’re actually learning …By contacting an HVAC technician, you can get your AC system’s suction pressure back to normal levels. If you are experiencing a problem with your air conditioning or heating call us at 512-336-1431 to schedule an appointment. We’ll be glad to come out and take a look at the issue. 1431-183 A/C & Heating proudly serves Round Rock ...hs,max = p0 ρ ⋅ g maximum suction head. In this formula, p 0 denotes the (ambient) pressure on the liquid surface and ϱ denotes the density of the liquid. For pumping water with a density of ϱ = 1000 kg/m³ the maximum suction head at an ambient pressure of 1 bar is thus 10 meters.Fig. 3.55 illustrates this by plotting the pump discharge head vs. flow for high- and low-suction tank conditions. The control valve, however, tries to maintain a steady pressure. As a result, the flow rate varies as the suction pressure varies. In some cases, the flow rate may drop to below the recommended minimum at very low head conditions.Terms in this set (24) When a redfrigeration systems's suction line is noticeably cold instead of just being cool, it probably contains___refrigerent. low-pressure liquid. When a refrigeration systems's liquid linw is noticably hot instead of just being warm. probably contains ____ refrigerant. high-pressure vapor.Net Positive Suction Head (NPSH) NPSH can be defined as two parts: NPSH Available (NPSHA): The absolute pressure at the suction port of the pump. AND. NPSH …we note (and you probably know better than I) that making sense of any refrigerant pressure reading requires also a note of the ambient temperature. If we take 75°F as an example point, R410 low side typical pressure would be about 120 psi and the high side between 410-420 psi. Your high side is a little low.Low suction pressures, high superheating, low amp draws, and low head pressures will result as a result. Is it possible that a bad reversing valve causes excessive head pressure? Higher-than-normal back pressure and lower-than-normal high-side pressure are usually associated with weak compressor valves and bleeding reversing valves, as well as ...When a refrigeration system that produces low or no cooling has high suction pressure and high head pressure , it probably A. has an inefficient compressor B. has a low-side restriction C. is overcharged D. is undercharged. Refrigeration and Air Conditioning Technology (MindTap Course List) 8th Edition. ISBN: 9781305578296.Air Flow " and " Max. Static Pressure " are listed as specifications. Air flow is the volume of air that is produced by the fan measured by time. In this case, the air flow of a fan is measured in cubic meters per minute (m³/min) in metric units, or cubic feet per minute (CFM) in imperial units. In simplest terms, if you have a 5 ft x 5 ft x 5 ...The compressor is still cooling, but not to its rated capacity, which can cause refrigerated products to spoil faster and frozen products to begin to thaw. There are three main reasons why a compressor will simultaneously have a low head pressure and a high suction pressure: 1. Bad (leaky) compressor valves; 2. Worn compressor rings; and.Lowering the head pressure will result in an increase in the frequency and magnitude of the surge. Conversely, increasing the head pressure will result in lower frequency and magnitude. With a melt pump, simply lowering and raising the suction pressure will give you an indication if a partially filled metering section is the problem, if …The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.1. Reduced Cooling Capacity. 2. Reduced Airflow From the Vents. 3. Increased Energy Consumption. 4. Poor Indoor Air Quality. How to Diagnose and Fix … A bad check valve on an air conditioner, heat pump or similar HVACR equipment can show up as abnormally low or abnormally high suction line pressures, or as abnormally low or high superheat. Experts suggest using an IR heat gun or similar tempeature measuring tool to check the tempeature of the refrigerant line on each side of the valve. The most common causes of pressure in the head and face include allergies, ear infections, the common cold, muscle tension, sinusitis, stress and tension headaches. Increased intra...Description: HHL-Flomax (High Head Low Flow) "HR" high pressure self-priming centrifugal pumps meet USCG specifications for auxiliary fire control. The high suction centerline and impeller design eliminates premature priming loss while ensuring consistent priming Discharge Size: 1.5 inch; Maximum Discharge Flow: 108 to 180 GPM; Power …It is possible to ensure that cavitation is avoided during pump operation by monitoring the net positive suction head of the pump. Net positive suction head for a pump is the difference between the suction pressure and …Repeatedly tripping sentronic+. 35 psi net oil press. No press difference between crank and suction. Crankcase heater working. R-22 40 psig suction 160 psig head, 8* sh at comp. sorry no sc data. 40* outdoor ambient. Sh measurements taken at each evap outlet right around 4*. No one evap showing major flooding.High head suction pressure. High suction pressure is a common problem in the cooling systems. It can cause due to improper functioning of the compressor. If the compressor is not delivering sufficient refrigerant to the system, the suction pressure will increase accordingly. One can understand the high head suction pressure with a better study ...Terms in this set (24) When a redfrigeration systems's suction line is noticeably cold instead of just being cool, it probably contains___refrigerent. low-pressure liquid. When a refrigeration systems's liquid linw is noticably hot instead of just being warm. probably contains ____ refrigerant. high-pressure vapor. Suction pressure occurs on the low-pressure side of the system where refrigerant is drawn into the compressor. Head pressure, or high side pressure, should not be confused with these other readings as each serves a specific purpose in maintaining an effective HVAC cycle. I just wanted to pick every ones brain i could. I am working on trane condensor and have high head pressure and low suction pressure. It was 90+ out today and I dumped r-22 into the system and no matter what I did I could not get the suction line to sweat and the superheat never dropped below about 20 degrees. my head pressure was around 285 ...Are you confused about all the different blood pressure readings? You aren’t alone. Read this quick guide to learn more about the difference between systolic and diastolic, what no...The superheat, SST, and suction pressure will be your key indicators of problems, including defrost issues, clogged TXV strainers, and airflow problems. Overall, rack refrigeration systems work best with high suction pressure and low liquid pressure. Nathan and Bryan also discuss: TD in rack refrigeration; Setting EPR valves; Rack sizingThe main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator …If suction pressures are low and the temperatures are close to freezing, the next step is to take the remaining measurements of your 5 Pillars (superheat, …Description: HHL-Flomax (High Head Low Flow) "HR" high pressure self-priming centrifugal pumps meet USCG specifications for auxiliary fire control. The high suction centerline and impeller design eliminates premature priming loss while ensuring consistent priming Discharge Size: 1.5 inch; Maximum Discharge Flow: 108 to 180 GPM; Power …The high side guage was connected to the liquid line. Static, both guages are 160 psig. When the unit ran, BOTH guages dropped to about 130. The high side was perhaps 2-5 higher. The amp draw at the compressor was 8.6 RLA out of a 22.1 suggest maximum on the equipment sticker.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.Liposuction is the removal of excess body fat by suction using special surgical equipment. A plastic surgeon typically does the surgery. Liposuction is the removal of excess body f...And, just as common, is suction pressure and/or head pressure being involved in the cause. Often, the refrigeration system will still run, but it’ll run inefficiently because the suction pressure is too high while the head pressure is simultaneously too low. ... Compressor amperes: low. Low side pressure: 11.6 psig/10° High side …Net Positive Suction Head. Net Positive Suction Head or NPSH for pumps can be defined as the difference between the suction pressure and the saturation pressure of the fluid, expressed in terms of height of liquid column. NPSH is used to measure how close a fluid is to saturated conditions. Lowering the pressure at the …NPSH Required (NPSHR): The minimum pressure required at the suction port of the pump to keep the pump from cavitating. NPSH or Net Positive Suction Head is a very important part of a pumping system. The systems NPSH A must be higher than the pump’s NPSH R in order for proper pump performance and to eliminate the risk of cavitation, which can ...Jun 11, 2021 · High head pressure is typically accompanied by a low suction pressure. This combination can be indicative of restricted refrigerant. Essentially, this means that air and vaporized water travel through your HVAC’s evaporator until they get to the top of the compressor, where it remains because it will not condense. temperature efficiency. 9. The approach temperature for the evaporator is. A. the difference between the suction and head pressures converted to temperature. B. the difference between the refrigerant boiling temperature and the suction-line temperature. C. the difference between the refrigerant boiling temperature and the inlet water temperature.System Information R22 2.5 ton: Low Side: 115. High Side: 240. Return Air: 83. Suction Line Temp: 75. Measured Super heat: 5. Super heat should be around 15. Low superheat is an indication that liquid refrigerant not changing state in the evaporator and is possibly flooding back to the compressor.This small amount of heat to reject will cause a low condensing pressure and temperature. Most of the refrigerant will then be stored in the condenser and receiver, simulating a pumped-down refrigeration system. Symptoms of a liquid line restriction include: Low evaporator (suction) pressure; High superheats;The suction pressure, also known as the low-side pressure, for a 404A cooler typically falls between 55-70 psi. This pressure ensures that the refrigerant evaporates at the desired temperature in the evaporator, providing efficient cooling. ... What causes high head pressure on a walk-in cooler? High head pressure in a walk-in cooler can be ...The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.Terms in this set (24) When a redfrigeration systems's suction line is noticeably cold instead of just being cool, it probably contains___refrigerent. low-pressure liquid. When a refrigeration systems's liquid linw is noticably hot instead of just being warm. probably contains ____ refrigerant. high-pressure vapor.When anxious and afraid, narwhals' pulse drops dangerously low. Narwhals are not cool under pressure. When stressed, they use up almost all of their energy in an instant by essenti...Study with Quizlet and memorize flashcards containing terms like The air entering a walk-in refrigerator air cooled condenser is 90°. What should the condensing temperature be?, The air entering a walk-in freezer air cooled condenser is 90°. What should the condensing temperature be?, The water temperature leaving a water cooled condenser is 100°. What does that indicate the condensing ...An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ...When the refrigerant is flowing in the suction line from the compressor to evaporator coil without any leakage or damaging the compressor’s piston and also there no impurities are present then the pressure range will be inside the system is 0.75 – 1.3 MP ,this called the High suction pressure normal head pressure. High suction pressure high ...Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on …R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.Low blood pressure, or hypotension, is generally not a concern and requires no treatment in healthy people, according to WebMD. Treatment of hypotension may require treatment of an...Terms in this set (54) In order for a system to operate correctly, the high side of the system must have enough _____. Vapor pumped, heat removed from condenser, vapor space. If there is a lack of refrigerant in a system, each pounds of refrigerant will not completely __________. Condense on the high side. When a system is undercharged, the ...The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. Also make sure the outdoor fan motor is running in the proper direction. Reply.1. Check Refrigerant Pressures. Hook-up refrigerant gauges to the pressure ports on the unit. Blue --> "True Suction" Low Pressure. Red --> High Pressure (Small liquid line) Allow the unit to run for 5-10 minutes. Monitor pressures as the system operates. Normal R-22 Suction Pressure = 60 - 80psig. 2.180 suction line pressure 320 discharge 10 degree temp split. No temp difference across the filter drier. I cleaned coils and checked airflow just to eliminate the variables. I recovered the refrigerant, changed the filter drier, charged about 2lbs before starting the compressor and the low side shot right up to 170. System holds about 8 lbs total.Terms in this set (24) When a redfrigeration systems's suction line is noticeably cold instead of just being cool, it probably contains___refrigerent. low-pressure liquid. When a refrigeration systems's liquid linw is noticably hot instead of just being warm. probably contains ____ refrigerant. high-pressure vapor.Blog. Pressure Points: Understanding the Importance of Head Pressure in HVAC. December 20, 2023by J & J Services. Table of ContentsToggle. Causes of High …Scale results in a low head pressure in the cooling mode and high suction pressure in the heating mode False A domestic hot water loop is loop is often used for heating domestic hot water from the hot discharge gas coming from the heat pump's refrigerant compressorSeptic shock is a serious condition that occurs when a body-wide infection leads to dangerously low blood pressure. Septic shock is a serious condition that occurs when a body-wide...are serviceable by a manufacturer-approved repair facility will lead to compressor inefficiency may cause high suction pressure and low head pressure Correct! All of the above. A suction line may also contain a ____. ... If a condenser has high head pressure and a higher than normal temperature, a technician could ____. ...To diagnose a bad TXV, look for: Low evaporator pressure. High evaporator and compressor superheats. Low compressor amp draw. Short cycling on the low-pressure control. Higher than normal discharge temperatures. Low condensing pressure. Low condenser split. Normal to high condenser subcooling.Summer is the perfect time to show off your style and express yourself through fashion. Whether you’re headed to a summer wedding, brunch with friends, or a day at the beach, you w... Suction pressure occurs on the low-pressure side of the system where refrigerant is drawn into the compressor. Head pressure, or high side pressure, should not be confused with these other readings as each serves a specific purpose in maintaining an effective HVAC cycle. Note that variations in the atmospheric pressure can and will affect the NPSHa value. Now you just need to convert the atmospheric pressure from psia to feet of head. Multiply 14.7 by 2.31, and the result is 33.957 feet, rounding to 34 feet. The value for the first component in the equation is 34 feet.Scale results in a low head pressure in the cooling mode and high suction pressure in the heating mode False A domestic hot water loop is loop is often used for heating domestic hot water from the hot discharge gas coming from the heat pump's refrigerant compressorIf you have high blood pressure or heart, liver, or kidney problems, your health care provider may suggest you lower your sodium intake. Look for these words on labels: low-sodium,...This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control; Somewhat high discharge temperature; Low condensing (head) pressure; Low condenser split; and.Low suction pressure causes. low suction pressure is developed in the refrigeration system. Some of the most probable causes are as below, The coil is covered with dust or frost. Restriction in the refrigerant line. Filters and strainers are dirty. Faulty fan motor. Low room temperature. Faulty compressor.If suction pressures are low and the temperatures are close to freezing, the next step is to take the remaining measurements of your 5 Pillars (superheat, …When a refrigeration system that produces low or no cooling has high suction pressure and high head pressure , it probably A. has an inefficient compressor B. has a low-side restriction C. is overcharged D. is undercharged. Refrigeration and Air Conditioning Technology (MindTap Course List) 8th Edition. ISBN: 9781305578296.The users should set high and low alarms on the EdP output to keep the DP tightly controlled while increasing the flow rate. If the pump doesn’t generate 120 feet total head at the 55 gpm flow rate, this could be your first indication of an operational or mechanical issue. Check the suction pressure and ensure it is greater than NPSHr.Design conditions and head pressure. High Head pressure for a refrigeration system, including a heat pump or air conditioner can cost you more money and possibly lead to premature failure of the compressor. It can also cause a malfunction in the system that will lead to reduced capacity for cooling and heat (for a heat pump) or the …The high head pressure may be due to ____. high ambient temperatures or reduced airflow through the condenser an overcharge of refrigerant, especially if it is a critically charged system Correct! All of the above. a thick coating of dirt and grime on the condenserFaulty valves in an open-drive compressor ____. will lead to compressor inefficiency may cause high suction pressure and low head pressure are serviceable by a manufacturer-approved repair facility All of the above. vibration absorber, a filter-drier, and an accumulator. A suction line may also contain a ____. vibration absorber, ...In the cooling mode, running in outdoor temperatures below 55 degree without a "low ambient control' will cause symptoms very similar to low refrigerant. The cold outside air will cause the head pressure to drop which, in-turn, causes the suction pressure to drop. Try blocking part of the outdoor fan discharge to increase head …1. Even though this is not the cause of high suction, Clean The Evaporator, because it needs to be clean. If it's dirty, it causes LOW suction pressure, and causes inexperienced techs to overcharge a system. 2. Just for kicks, and for a learning experience, check the system vitals, and record the pressures, water temp entering and leaving the ...Hi, I just put a new compressor on a gas pack. I charged it to the correct amount of refrigerant o the name tag. My ambient temp. is 100 degrees and the unit running with a high high side pressure a high suction pressure and high superheat and sub cooling. The indoor temp is 87 degrees. i was told that the high indoor temp is why my …This will cause low suction pressures, high superheats, low amp draws, and low head pressures. Also, the symptoms of a restricted TXV system are very similar to a system with a refrigerant undercharge. However, the undercharged system will have low subcooling levels. Technicians often confuse an undercharged system with a restricted …Design or measured suction pressure for a fan is Ps = -380 mm W.G. (-14 in W.G). The correction factor from table above 1.04. For a proper fan selection the suction pressure should be corrected to. Psc = (-380 mm W.G) 1.04. = -395 (mm W.G.) High suction pressure at a fan inlet decreases the density of air - and should be corrected for proper ...Jun 11, 2021 · High head pressure is typically accompanied by a low suction pressure. This combination can be indicative of restricted refrigerant. Essentially, this means that air and vaporized water travel through your HVAC’s evaporator until they get to the top of the compressor, where it remains because it will not condense. Lennox Learning Solutions teaches you what causes high head pressure on a heat pump in the heating mode.There is several factors that can cause hight pressur...The compressor is still cooling, but not to its rated capacity, which can cause refrigerated products to spoil faster and frozen products to begin to thaw. There are three main reasons why a compressor will simultaneously have a low head pressure and a high suction pressure: 1. Bad (leaky) compressor valves; 2. Worn compressor rings; and.To diagnose a bad TXV, look for: Low evaporator pressure. High evaporator and compressor superheats. Low compressor amp draw. Short cycling on the low-pressure control. Higher than normal discharge temperatures. Low condensing pressure. Low condenser split. Normal to high condenser subcooling.High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps.A ratio of head pressure to suction pressure is your compression ratio. Higher compression ratios tend to lead to reduced compressor performance (moving fewer BTUs). Even though we tend to see high head pressure as the main problem to avoid, we should be aware that low head pressure is possible.If it is a restriction, it will have high subcooling. Low Outdoor Ambient. When a cooling system is operated during low outdoor temperatures, the condensing temperature and head pressure will drop. If the head pressure drops low enough, the suction pressure will also drop, resulting in freezing.Advertisement ­C­lusters are now being used on a smaller scale for sensors. For instance, a traditional pressure sensor contains a device that outputs a varying voltage depending o...Karcher pressure washers are renowned for their powerful cleaning abilities and durability. However, like any mechanical device, they can encounter issues over time. One of the mos...temperature efficiency. 9. The approach temperature for the evaporator is. A. the difference between the suction and head pressures converted to temperature. B. the difference between the refrigerant boiling temperature and the suction-line temperature. C. the difference between the refrigerant boiling temperature and the inlet water temperature.

High Suction Pressure! I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI and my sub-cooling is around 40-50 Degrees. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and .... Car max orlando

high suction pressure and low head pressure

Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so.Try our Net positive suction head calculator or: In your reservoir, get fluid surface pressure: P surface. Get the distance between the pump and liquid surface: Z. If the tank is above the pump, multiply this value by -1. Obtain the vapor pressure for the system's temperature: P vapor. Also, its density is ρ. Note that g represents gravity.To diagnose a bad TXV, look for: Low evaporator pressure. High evaporator and compressor superheats. Low compressor amp draw. Short cycling on the low-pressure control. Higher than normal discharge temperatures. Low condensing pressure. Low condenser split. Normal to high condenser subcooling.Low suction/High head. I have a carrier 38QRF024300 with a 40QNQ024 unit I be been having issues with. Originally my readings were 157# suction (410A) and 275# head reading 7,5.2, and 4.1 amps when RLA is 12.8; with 5 degrees of subcooling. Ambient is 80 in parking garage.Design or measured suction pressure for a fan is Ps = -380 mm W.G. (-14 in W.G). The correction factor from table above 1.04. For a proper fan selection the suction pressure should be corrected to. Psc = (-380 mm W.G) 1.04. = -395 (mm W.G.) High suction pressure at a fan inlet decreases the density of air - and should be corrected for proper ...Repeatedly tripping sentronic+. 35 psi net oil press. No press difference between crank and suction. Crankcase heater working. R-22 40 psig suction 160 psig head, 8* sh at comp. sorry no sc data. 40* outdoor ambient. Sh measurements taken at each evap outlet right around 4*. No one evap showing major flooding.Apple's antitrust defense is moot after a narrow court decision on Monday morning....AAPL Apple (AAPL) shares are feeling even more pressure as the Supreme Court adds to the ba...What is High Head Pressure for 410A . High head pressure for 410A is an indication of a system that has lost its ability to evaporate refrigerant correctly. This can be caused by many things including low charge, clogged air filters, restricted airflow, or dirty coils. High head pressure creates higher discharge temperatures and forces the ...In the cooling mode this will result in low suction pressure and low discharge pressure. Sub cooling would be extra high. However, heatpumps can't always be charged accurately using sub cooling alone. Usually "a stuck check valve" can be freed-up by using a strong magnet.Hi, I just put a new compressor on a gas pack. I charged it to the correct amount of refrigerant o the name tag. My ambient temp. is 100 degrees and the unit running with a high high side pressure a high suction pressure and high superheat and sub cooling. The indoor temp is 87 degrees. i was told that the high indoor temp is why my …Scale results in a low head pressure in the cooling mode and high suction pressure in the heating mode. False. A domestic hot water loop is loop is often used for heating domestic hot water from the hot discharge gas coming from the heat pump's refrigerant compressor. True..